An. acad. bras. ciênc ; 80(2): 253-262, June 2008. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-482879

RESUMEN

Four sensitive and rapid methods for the determination of stavudine (STV) in bulk drug and in dosage forms were developed and optimized. In titrimetry, aqueous solution of STV was treated with a known excess of bromate-bromide in HCl medium followed by estimation of unreacted bromine by iodometric back titration. Spectrophotometric methods involve the addition of a measured excess of bromate-bromide in HCl medium and subsequent estimation of the residual bromine by reacting with a fixed amount of methyl orange, indigocarmine or thymol blue followed by measurement of absorbance at 520 nm (method A), 610 nm (method B) or 550 nm (method C). In all the methods, the amount of bromate reacted corresponds to the amount of STV. Calculations in titrimetry were based on a 1:0.666 (STV:KBrO3) stoichiometry and the method was found to be applicable over 3.5-10 mg range. A linear increase in absorbance with concentration of STV was observed in the spectrophotometric methods, and the Beer's law was obeyed over the concentration ranges 0.125-1.75, 1-10 and 1-9.0 µg mL-1 STV for method A, method B and method C, respectively. The methods when applied to the determination of STV in tablets and capsules were found to give satisfactory results.


Este trabalho descreve quatro métodos rápidos e sensíveispara a determinação de estavudina (STV) na matéria-prima ou em produtos formulados. Soluções aquosas de STV podem ser tituladas tratando-as com excesso de bromato-brometo em meio ácido clorídrico, seguido da determinação iodimétrica de bromo em excesso. Métodos espectrofotométricos tambémenvolvem a adição de excesso de bromato-brometo à amostra, seguida da determinação de bromo residual por adição de uma quantidade fixa de alaranjado de metila, índigo-carmim ou azul de timol, e de medidas de absorbância nos comprimentos de onda apropriados: 520, 610 ou 550 nm. Em todos os métodos, a quantidade de bromato consumida corresponde à quantidade de STV e os resultados da sua aplicação à determinação de STV em comprimidos e cápsulas são satisfatórios.


Asunto(s)
Bromatos , Bromuros , Colorantes , Preparaciones Farmacéuticas/química , Estavudina/análisis , Compuestos Azo , Cápsulas , Carmin de Índigo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrofotometría/métodos , Comprimidos , Timolftaleína/análogos & derivados , Volumetría/métodos
2.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 43(3): 471-479, jul.-set. 2007. ilus, tab
Artículo en Inglés | LILACS | ID: lil-468154

RESUMEN

Three new methods are described for the assay of stavudine (STV) in bulk drug and in dosage forms using chloramine-T (CAT) and two dyes, methyl orange and indigocarmine, as reagents. Titrimetry involves treating STV with a measured excess of CAT in hydrochloric acid medium, and after the oxidation of STV is judged to be complete, the unreacted oxidant is determined iodometrically. Spectrophotometric methods entail the addition of a known excess of CAT to STV in hydrochloric acid medium followed by determination of residual oxidant by reacting with a fixed amount of either methyl orange and measuring the absorbance at 520 nm (Method A) or indigo carmine and measuring the absorbance at 610 nm (Method B). In all the methods, the amount of CAT reacted corresponds to the amount of STV. In titrimetric method, the reaction follows 1:1 stoichiometry (STV: CAT), and is applicable over the range 1.5-10 mg of STV. In spectrophotometric methods, the absorbance is found to increase linearly with concentration of STV. The systems obey Beer's law for 0.2-2.0 and 1.0-10.0 mg/mL for method A and method B, respectively. The apparent molar absorptivities are calculated to be 5.7x10(4) and 1.5x10(4) L/mol/cm for method A and method B, respectively, and the corresponding Sandell sensitivity values are 0.004 and 0.015 µg/cm². The limits of detection and quantification are reported for both methods. Intra-day and inter-day precision and accuracy of the developed methods were evaluated as per the current ICH guidelines. The methods were successfully applied to the assay of STV in tablet and capsule formulations and the results were compared with those of a reference method by applying Student's t-test and F-test. No interference was observed from common tablet adjuvants. The accuracy and reliability of the methods were further ascertained by performing recovery experiments via standard-addition method.


Descrevem-se três novos métodos para o ensaio de estavudina (STV) na matéria-prima e nas formulações utilizando-se clroamina-T (CAT) e dois corantes, alaranjado de metila e índigo carmim como reagentes. A titulação envolve o tratamento de STV com excesso medido de CAT em meio de ácido clorídrico, e, quando a oxidação se completar, o oxidante que não reagiu é determinado iodometricamente. Os métodos espectrofotométricos compreendem a adição de excesso conhecido de CAT ao STV em ácido clorídrico, seguida da determinação do oxidante residual por meio da reação com quantidade fixada de alaranjado de metila, medindo-se a absorvância a 520 nm (Método A) ou índigo carmim, medindo-se a absorvância a 610 nm (Método B). Em todos os métodos, a quantidade de CAT que reagiu corresponde à quantidade de STV. No método titulométrico, a reação segue a estequiometria 1:1 (STV:CAT) e é aplicável na faixa de 1,5 a 10 mg de STV. Nos métodos espectrofotométricos, a absorvância aumenta linearmente com a concentração de STV. Os sistemas obedecem a lei de Beer nos intervalos de 0,2 a 2,0 mg/mL e 1,0 a 10,00 mg/mL para os métodos A e B, respectivamente, e os valores de sensibilidade de Sandell correspondentes são 0,004 e 0,015 µg/cm². Os limites de detecção e de quantificação são apresentados para ambos os métodos. A precisão e a exatidão intra-dia e inter-dia dos métodos desenvolvidos são avaliadas de acordo com as normas ICH. Os métodos foram aplicados com êxito aos ensaios de STV em comprimidos e em cápsulas e os resultados foram comparáveis com aqueles obtidos com o método de referência, utilizando-se o teste t de Student e o teste F. Não se observou interferência dos adjuvantes comuns em comprimidos. A exatidão e a confiabilidade dos métodos foram ajustadas por meio de experimentos de recuperação via método de adição de padrão.


Asunto(s)
Cloraminas/administración & dosificación , Estavudina/análisis , Espectrofotometría/métodos , Volumetría/métodos